Jual Water meter Digital KROHNE type OPTIFLUX 4000 (Electromagnetic Flow meter)

Electromagnetic flow sensor
• Robust, fully welded construction
• Standard solutions for the widest range of industrial applications
• Engineered solutions for very demanding applications

 

Measuring system
Measuring principle : Faraday’s law
Application range : Electrically conductive fluids
Measured value
Primary measured value : Flow velocity
Secondary measured value : Volume flow
Design
Features :

Fully welded maintenance-free sensor.
Flange version with full bore flow tube.
Standard as well as higher pressure ratings.
Broad range of nominal sizes.
Industry specific insertion lengths.
Modular construction : The measurement system consists of a flow sensor and a signalconverter. It is available as compact and as separate version.
Compact version:

With IFC 040 converter: OPTIFLUX 4040 C
With IFC 100 converter: OPTIFLUX 4100 C
With IFC 300 converter: OPTIFLUX 4300 C

Remote version :

In wall (W) mount version with IFC 100 converter : OPTIFLUX 4100 W
In field (F), wall (W) or rack (R) mount version with IFC 300 converter:
OPTIFLUX 4300 F, W or R

Nominal diameter :

With IFC 040 converter: DN10… 150 / 3/8… 6″
With IFC 100 converter: DN2.5…1200 / 1/10…48″
With IFC 300 converter: DN2.5…3000 / 1/10…120″

Measuring accuracy
Reference conditions

Medium : water
Temperature : 10…30°C / 50…86°F
Operating pressure : 1 bar / 14.5 psig
Inlet section : ≥ 5 DN
Electrical conductivity : ≥ 300 μS/cm
Flow conditions similar to EN 29104

Maximum measuring error :

These values are related to the pulse / frequency output.
Related to volume flow (MV = Measured Value)
With IFC 040 converter:
v < 1 m/s / 3.3 ft/s: ± 5 mm/s
v > 1 m/s / 3.3 ft/s: ± 0.5 % of MV
With IFC 100 converter:
DN2.5…6: ± 0.4% of MV + 1 mm/s
DN10…1200: ± 0.3% of MV + 1 mm/s
With IFC 300 converter:
DN2.5…6: ± 0.3% of MV + 2 mm/s
DN10…1600: ± 0.2% of MV + 1 mm/s
DN1800…3000: ± 0.3% of MV + 2 mm/s
The additional typical measuring deviation for the
current output is ±10 μA.
The maximum measuring error depends on the installation
conditions.
For detailed information refer to Measurement accuracy on page 21

Repeatability : ±0.1% of MV, minimum 1 mm/s
Calibration / Verification

Standard:
Wet calibrated on EN 17025 accredited calibration rig by direct
volume comparison.
Optional:
Verification to Measurement Instrument Directive (MID),
Annex MI-001.
Standard: Verification at Ratio (Q3/Q1) = 80, Q3 ≥ 2 m/s
Optional: Verification at Ratio (Q3/Q1) > 80 on request
(Only in combination with IFC 300)
Long term stability : ±0.1% of MV
Special calibration : On request.
MID Annex MI-001 (Directive 2004/22/EC):
EC-Type examination certificate to MID Annex MI-001
(Only in combination with IFC 300)
Diameter range: DN25…500
Forward and reverse (bi-directional) flow
Liquid temperature range: +0.1°C / 50°C
For detailed information refer to Legal metrology on page 15

OIML R49

Certificate of conformity to OIML R49 : (Only in combination with IFC 300)

Diameter range

Class 1: DN80…500
Class 2: DN25…50
Forward and reverse (bi-directional) flow
Liquid temperature range: +0.1°C / 50°C

 

 

 