Jual Water meter Digital KROHNE type OPTIFLUX 5000 Sandwich (Electromagnetic Flowmeter)

Measuring system
Measuring principle : Faraday’s law
Application range : Electrically conductive fluids

Measured value
Primary measured value Flow velocity
Secondary measured value : Volume flow, mass flow, electrical conductivity, coil temperature

Design

Features : Sandwich version with optimized flow tube
Modular construction : The measurement system consists of a flow sensor and a signal converter. It is available as compact and as separate version. More information about the signal converter can be found in the documentation of the signal converter.
Compact version :
With IFC 100 converter: OPTIFLUX 5100 C
With IFC 300 converter: OPTIFLUX 5300 C
Remote version :
In wall (W) mount version with IFC 100 converter: OPTIFLUX 5100 W
In field (F), wall (W) or rack (R) mount version with IFC 300 converter:
OPTIFLUX 5300 F, W or R
Nominal diameter : DN2.5…100 / 1/10…4″
Measurement range : -12…+12 m/s / -40…+40 ft/s
Measuring accuracy
Reference conditions Medium: water
Temperature: 20°C / 68°F
Inlet section: 10 DN
Outlet section: 5 DN
Flow velocity: > 1 m/s / > 3 ft/s
Operating pressure: 1 bar / 14.5 psig
Valve closing time variation: < 1 ms
Wet calibrated on EN 17025 accredited calibration rig by direct volume
comparison.
Maximum measuring
error
Related to volume flow (MV = Measured Value).
These values are related to the pulse / frequency output.
The additional typical measuring deviation for the current output is ±10 μA.
For detailed information refer to Measuring accuracy on page 12.
Repeatability ±0.1% of MV, minimum 1 mm/s
Long term stability ±0.1% of MV